Vaporization Rate
100 LB Propane Cylinders (approximate)
Maximum Continuous Draw In BTU Per Hour At Various Temperatures In Degrees F. Green = 100% output (80,000 BTU for this heater)

100 lb Cylinder Propane Tank
100 LB Propane Cylinders (approximate)
Maximum Continuous Draw In BTU Per Hour At Various Temperatures In Degrees F. Green = 100% output (80,000 BTU for this heater)
Lbs. of Propane in Cylinder |
0 degree F 1 Tank |
20 degree F 1 Tank |
0 degree F 2 Tanks |
20 degree F 2 Tanks |
0 degree F 3 Tanks |
20 degree F 3 Tanks |
100 | 113,000 | 167,000 | 248,000 | 367,000 | 545,000 | 807,000 |
90 | 104,000 | 152,000 | 228,000 | 334,000 | 501,000 | 734,000 |
80 | 94,000 | 137,000 | 206,000 | 301,000 | 400,000 | 662,000 |
70 | 83,000 | 122,000 | 182,000 | 268,000 | 363,000 | 589,000 |
60 | 75,000 | 109,000 | 165,000 | 239,000 | 310,000 | 453,000 |
50 | 64,000 | 94,000 | 141,000 | 206,000 | 260,000 | 382,000 |
40 | 55,000 | 79,000 | 121,000 | 174,000 | 217,000 | 319,000 |
30 | 45,000 | 66,000 | 99,000 | 145,000 | 217,000 | 319,000 |
20 | 36,000 | 51,000 | 79,000 | 112,000 | 174,000 | 246,000 |
10 | 28,000 | 38,000 | 62,000 | 84,000 | 136,000 | 184,000 |

Premier 170 |
Premier 80 |
||
Heat Rating
|
|||
Intermediate Input/Output (Btu/h)
|
– | – | |
Max (Input/Output) (Btu/h)
|
170,000 | 80,000 | |
Configurations Available
|
|||
Ignition Type
|
Direct Spark | Direct Spark | |
Heated Air Output
|
|||
Heated Air Output (CFM)
|
1200 | 450 | |
Fuel Consumption (max)
|
|||
LPG (lbs./hr.)
|
7.9 | 3.7 | |
NG (cu. ft./hr.)
|
170.0 | 80 | |
Inlet Gas Pressure
|
|||
LPG min/max (W.C.)
|
11.0 / 13.5 | 11 / 13.5 | |
NG min/max (W.C.)
|
7.0 / 13.5 | 7 / 13.5 | |
Electrical Supply
|
|||
Amps (Starting/Cont. Oper.)
|
8 / 2.58 / 2.5 | 5 / 1.5 | |
Electrical Requirements (Volts/Hz/Phase)
|
115 / 60 / 1 | 115 / 60 / 1 | |
Dimensions
|
|||
Height (in.)
|
28.0 | 20.0 | |
Length (in.)
|
31.0 | 29.5 | |
Width (in.)
|
18.0 | 13.5 | |
Weight
|
|||
Net Weight (lbs.)
|
126 | 67 | |
Shipping Weight (lbs.)
|
134 | 74 | |
Materials
|
|||
Case Material | Tri-Shield Steel | Tri-Shield Steel | |
Add’l Features/Options
|
|||
Ducting
|
Opt. | Opt. | |
End Diffuser
|
Opt. | Opt. | |
Gas Hose (10ft U.S./15ft. Can)
|
Std. | Std. | |
Gas Hose (15ft U.S./15ft. Can)
|
N/A | N/A | |
Gas Pressure Regulator (with POL)
|
Std. | Std. | |
Thermostat (w/ 20 ft cord)
|
Std. | Std. | |
Unit Diffuser
|
Opt. | Opt. | |
Certifications
|
|||
CSA-Canada
|
Yes | Yes | |
CSA-U.S.
|
Yes | Yes |